ReliabilitySafetyCapacity

RHI-3P(5-10)K-HVES-5G

5K/6K/8K/10K

UPS function, Less than 40ms reaction, does not affect the power supply of important loads; 24 hours solar energy use; save money up to zero cost;
Optional 24-hour load consumption monitoring solutionfanless design, long lifespan; Easy monitor setup via remote APP settings;
Regulate peak and valley electricity consumption, low-cost charging at night, and high-priced electricity sales at daytime;
Easy O & M, remotely control and upgrade any selected inverter, making digital power plant maintenance at your fingertips.

Hybrid Energy Storage Inverter

Leading Features

  • Max. efficiency 98.4%%
  • Intelligent EMS function
  • Support three-phase imbalance
  • 2 MPPT and 4 DC input; Max 26A DC input current
  • Time of use shifting and peak shaving capabilities to grid
  • Solis supply optional arc fault circuit interrupter (AFCI) function
  • Remotely control and upgrade any selected inverter
  • Power supply can be switched automatically and switching time within 40ms
  • Ensures AC backup for up to 10kW of continuous power and 16kVA of peak power
  • 24-hour fully intelligent energy management system for monitor production and consumption
  • three operating modes (self-consumption; time-of-use; off-grid back-up) & programmable energy management

Technical Specifications

Input DC(PV side)

  • Max. input voltage
    1000 V
  • Rated voltage
    600 V
  • Start-up voltage
    160 V
  • MPPT voltage range
    200-850 V
  • Max. input current
    13 A / 13 A
  • Max. short circuit current
    19.5 A / 19.5 A
  • MPPT number/Max input strings number
    2/2

Battery

  • Communication interface
    CAN/RS485
  • Battery voltage range
    160~600 V
  • Max. charge/discharge power
    5 kW
  • Max.charge/discharge current
    25 A

Output AC (Grid side)

  • Max. apparent output power
    5 kVA
  • Operation phase
    3/N/PE
  • Rated grid voltage
    380 V / 400 V
  • Rated grid frequency
    50 Hz / 60 Hz
  • Rated grid output current
    7.6 A / 7.2 A
  • Max. output current
    8.4 A
  • Power factor
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi
    <2%

Output AC (Back-up)

  • Max. apparent output power
    5 kVA
  • Peak apparent output power
    10 kVA, 60 sec
  • Back-up switch time
    < 40 ms
  • Rated output voltage
    3/N/PE, 380 V / 400 V
  • Rated frequency
    50 Hz / 60 Hz
  • Rated output current
    7.6 A / 7.2 A
  • Max. output current
    8.4 A
  • THDi
    <2%

Efficiency

  • EU efficiency
    97.7%
  • MPPT efficiency
    99.9%
  • Battery charge/discharge Efficiency
    97.5%

Protection

  • Output over current protection
    Yes
  • Output short protection
    Yes
  • DC switch
    Yes
  • DC reverse-polarity protection
    Yes
  • PV over voltage protection
    Yes
  • Battery reverse protection
    Yes

General Data

  • Weight
    25.1 kg
  • Topology
    Transformerless
  • Self consumption (night)
    <7 W
  • Operating ambient temperature range
    -25 ~ +60°C
  • Relative humidity
    0~100%
  • Ingress protection
    IP65
  • Cooling concept
    Natural convection
  • Max. operation altitude
    4000 m
  • Safety/EMC standard
    IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-3
  • Grid connection standard
    G98 or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15/VFR:2019, RD 1699/RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA

Features

  • AC connection
    Quick connection plug
  • Display
    LCD
  • Communication
    RS485, Optional: Wi-Fi, GPRS