Select Your Region

Asia/Pacific
中国 India Việt nam 대한민국 Australia ราชอาณาจักรไทย پاکستان
Europe
Türkiye United Kingdom France Deutschland Nederland España Polska Україна Italia Sverige
North America
United States México Canada
South America
Brasil
Africa
South Africa
Other Countries and Regions
Other Countries and Regions

Reliability     Safety    Capacity

S5-GP1P(7-10)K

7K/8K/9K/10K

S5-GR1P(7-10)K series inverter is designed for residential PV plants. 3 MPPTs design can effectively reduce string mismatch. Compact and lightweight design, bring easy installation. The protection level is increased to IP66. Integrated AFCI function can proactively reduce the risk of fire.

7-10kW Single Phase Inverter

Leading Features

  • Max. efficiency 98.0%

  • Max. input current 14A
  • Compact and lightweight
  • Super high frequency switching technology
  • Wide voltage range and low startup voltage
  • 3 MPPT design with precise MPPT algorithm
  • AFCI protection, proactively reduces fire risk
  • Friendly and adaptable connection to the grid

Technical Specifications

Input DC

  • Max. input voltage
    600 V
  • Rated voltage
    330 V
  • Start-up voltage
    120 V
  • MPPT voltage range
    100-500 V
  • Max. input current
    14 A / 14 A / 14 A
  • Max. short circuit current
    22 A / 22 A / 22 A
  • MPPT number
    3
  • Max. input strings number
    3

Output AC

  • Max. apparent output power
    7.7 kVA
  • Max. output power
    7.7 kW
  • Rated grid voltage
    1/N/PE, 220V / 230 V
  • Rated grid frequency
    50 Hz / 60 Hz
  • Rated grid output current
    31.8 A / 30.4 A
  • Max. output current
    33.7 A
  • Power factor
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi
    <3%

Efficiency

  • EU efficiency
    97.1%

Protection

  • Short circuit protection
    Yes
  • Output over current protection
    Yes
  • Surge protection
    Yes
  • Grid monitoring
    Yes
  • Anti-islanding protection
    Yes
  • Temperature protection
    Yes
  • Integrated DC switch
    Optional
  • Integrated AFCI (DC arc-fault circuit protection)
    Yes (Activation required)

General Data

  • Weight
    18.5 kg
  • Topology
    Transformerless
  • Self-consumption (night)
    <1 W
  • Operating ambient temperature range
    -25~+60℃
  • Relative humidity
    0-100%
  • Ingress protection
    IP66
  • Cooling concept
    Natural convection
  • Max. operation altitude
    4000 m
  • Safety/EMC standard
    IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
  • Grid connection standard
    G99, EN 50549-1, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530

Features

  • AC connection
    OT Terminal
  • Display
    LCD
  • Communication
    RS485, Optional: Wi-Fi, GPRS

Sales Inquiries:europesales@solisinverters.com