Select Your Region

Asia/Pacific
中国 India Việt nam 대한민국 Australia
Europe
Türkiye United Kingdom France Deutschland Nederland España Polska Україна Italia Sverige
North America
United States México
South America
Brasil
Africa
South Africa
Global language
Global language

Reliability    Safety    Capacity

S5-GC(50-70)K

400V: 50K/60K      480V: 60K-HV/70K-HV

S5-GC(50-70)K three phase series string inverter are suitable for the installation of three-phase input pv system of commercial and industrial PV plants. Adopt 5/6 MPPT desigh to provide a more flexible configuration scheme and higher generation efficiency. Perfect commercial site monitoring solution, intelligent redundancy fan.

50-70K Three Phase Inverter

Features

  • Max. efficiency 98.7%

  • String current up to 16A
  • Night time SVG function
  • Supports export power control
  • IP66
  • Intelligent redundant fan-cooling
  • DC side supports "Y" connectors
  • Supports aluminium wire access to reduce cost
  • AFCI protection, proactively reduces fire risk
  • 10/12 string inputs allow for 150%+ DC oversizing
  • Intelligent string monitoring. Smart I-V curve scan
  • Globally recognised branded componentry for longer life
  • 5/6 MPPT design, supports multiple orientation system design
  • Integrated PID recovery function, increases overall system yield
  • Scan to register on SolisCloud, supports remote upgrade and control
  • Supports PLC/GPRS/WiFi communication with less wiring and reduced installation costs

Technical Specifications

Input DC

  • Rated voltage
    600 V
  • Start-up voltage
    195 V
  • MPPT voltage range
    180-1000 V
  • Max. input current
    5*32 A
  • Max. short circuit current
    5*50 A
  • MPPT number/Max. input strings number
    5/10

Output AC

  • Max. apparent output power
    55 kVA
  • Max. output power
    55 kW
  • Rated grid voltage
    3/N/PE, 220 V / 380 V, 230 V / 400 V
  • Rated grid frequency
    50 Hz / 60 Hz
  • Rated grid output current
    76.0 A /72.2 A
  • Max. output current
    83.6 A
  • Power Factor
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi
    <3%

Efficiency

  • EU efficiency
    98.3%

Protection

  • Short circuit protection
    Yes
  • Output over current protection
    Yes
  • Surge protection
    DC Type II / AC Type II
  • Grid monitoring
    Yes
  • Anti-islanding protection
    Yes
  • Temperature protection
    Yes
  • Strings monitoring
    Yes
  • I/V Curve scanning
    Yes
  • Integrated PID recovery
    Optional
  • Intergarated DC switch
    Optional
  • Integrated AFCI (DC arc-fault circuit protection)
    Optional

General Data

  • Weight
    54.5 kg
  • Topology
    Transformerless
  • Self consumption (night)
    <1 W
  • Operating ambient temperature range
    -25 ~ +60°C
  • Relative humidity
    0-100%
  • Ingress protection
    IP66
  • Cooling concept
    Intelligent redundant fan-cooling
  • Max. operation altitude
    4000 m
  • Safety/EMC standard
    IEC 62109-1/-2, IEC62116 & IEC 61000-6-1/-2/-3/-4
  • Grid connection standard
    VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99,EN 50549-1/-2, NTS 631, UNE 206006, UNE 206007-1, IEC61727, DEWA

Features

  • AC connection
    OT terminal (max. 70 mm²)
  • Display
    LCD, Capacitive touch buttons
  • Communication
    RS485, USB, Optional: Wi-Fi, GPRS, PLC

Sales Enquiries: sales@ginlong.com
Copyright@2019 Ginlong Technologies All rights reserved
Captcha*