Ordering: S6-EH1P(3.8-11.4)K-H-US
• APST (APS MLRSD Transmitter)
• RSS (Tigo MLRSD Transmitter)
• ENT (Enteligent MLRSD Transmitter)
The S6 (Series 6) hybrid energy storage inverter is the latest Solis US model certified to IEEE 1547-2018, UL 1741 SA & SB, and SunSpec Modbus, providing economical zero-carbon power from an all-weather (NEMA 4X / IP 66) high-efficiency PV string inverter. This new PV / Battery inverter can be dc-coupled to a variety of certified high-voltage Lithium batteries. The S6 hybrid is a grid-forming inverter that supports the latest large PV modules with high current (16 amp) dc inputs at each MPPT.
Four MPPTs allows for versatile PV array design
UL 1741 SB certified, California Rule 21 compliant
Maximum PV input current up to 16A per string
High DC:AC ratio of 1.6 for more PV power capacity
Transfer time is < 10ms for all backed up loads
SunSpec modbus certified with the latest SunSpec models
Provides split-phase backup power without an external ATR
Multiple working modes to meet different use case scenarios
Third-party tested and validated for product reliability
Can be used for both whole-home and dedicated loads backup systems
DC to DC battery charging for optimal use of PVgenerated energy
Reverse DC polarity protection and software-based AFCI detection
Offers all of the smart inverter functions detailed in IEEE 1547-2018
Solis app allows for remote system configuration and firmware upgrading
Generates up to 50A/11.4kW of continuous backup power with just one inverter
Capable of frequency-watt control for interoperability with other smart devices
NEC 2017 compliant with multiple integrated PLC transmitter options available
Fanless design using convection cooling for lower failure rate and complexity
Utilizes an energy management system that maximizes efficiency and offers multiple operating modes
UL 9540 certified with multiple battery brands to provide up to 150 kWh of storage capacity per inverter
Supports generator interconnection and allows the generator to function as the grid source if utility power is lost
Max. apparent output power
Back-up switch time
Rated output voltage (L1-L2)
Rated output voltage (L1/L2-N)
AC output voltage range
Rated grid frequency
Frequency range
Rated AC output current
Max. output overcurrent protection, 10 sec
Backup support configurations
Power factor
THDv (@linear load)
PV CEC efficiency 97.2%
BAT charged by PV Max. efficiency 98.5%
BAT charged/discharged to AC Max. efficiency 97.0%
Residual (leakage) current detection
Integrated AFCI (DC arc-fault circuit protection)
DC reverse-polarity protection
Rapid Shutdown NEC 2017
Compatible RSD Receivers
Protection class/Over voltage category
Manual inverter bypass switch
Weight
Mounting type
Topology
Self-consumption (night)
Operation temperature range
Ingress protection
Noise emission
Cooling method
Max. operation altitude
Compliance
Generator support
AC connection
Interface
Monitoring platform
Integrated ANSI C12.20 revenue grade meter
Communication
Integrated RSD Transmitter Brands