Select Your Region

Asia/Pacific
中国 India Việt nam 대한민국 Australia
Europe
Türkiye United Kingdom France Deutschland Nederland España Polska Україна Italia Sverige
North America
United States México
South America
Brasil
Africa
South Africa
Global language
Global language

80-110kW Three Phase Inverter

Leading Features

  • 9/10 MPPTs, max. efficiency 99%
  • > 150% DC/AC ratio
  • Compatible with bifacial modules
  • IP66
  • Night SVG function
  • Built-in PID recovery for better module performance (optional)
  • Globally recognised branded componentry for longer life
  • Intelligent string monitoring. Smart I-V curve scan
  • Remote firmware upgrade with simple operation
  • Power line communication (PLC) (optional)
  • Support "Y" type connection in DC side
  • Supports aluminium wire access to reduce cost

Installation video

Installation video

Technical Specifications

Input DC

  • Rated voltage
    600 V
  • Start-up voltage
    195 V
  • MPPT voltage range
    180-1000 V
  • Max. input current
    9*26 A
  • Max. short circuit current
    9*40 A
  • MPPT number
    9
  • Max. input strings number
    18

Output AC

  • Max. apparent output power
    88 kVA
  • Max. output power
    88 kW
  • Rated grid voltage
    3/N/PE, 220 V / 380 V, 230 V / 400 V
  • Rated grid frequency
    50 Hz / 60 Hz
  • Rated grid output current
    121.6 A / 115.5 A
  • Max. output current
    133.7 A
  • Power Factor
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi
    <3%

Efficiency

  • EU efficiency
    98.3%

Protection

  • Short circuit protection
    Yes
  • Output over current protection
    Yes
  • Surge protection
    DC Type II / AC Type II
  • Grid monitoring
    Yes
  • Anti-Islanding protection
    Yes
  • Temperature protection
    Yes
  • Strings monitoring
    Yes
  • I/V Curve scanning
    Yes
  • Integrated PID recovery
    Optional
  • Integrated AFCI (DC arc-fault circuit protection)
    Yes
  • Integrated DC switch
    Yes
  • Integrated AC switch
    Optional

General Data

  • Weight
    82 kg
  • Topology
    Transformerless
  • Self consumption (night)
    <2 W
  • Operating ambient temperature range
    -25 ~ +60°C
  • Relative humidity
    0~100%
  • Ingress protection
    IP66
  • Cooling concept
    Intelligent redundant fan-cooling
  • Max.operation altitude
    4000 m
  • Safty/EMC standard
    IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4
  • Grid connection standard
    G98 or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530

Features

  • AC connection
    OT terminal (max. 185 mm²)
  • Display
    LCD
  • Communication
    RS485, Optional: Wi-Fi, GPRS, PLC
Sales Enquiries: sales@ginlong.com
Copyright@2019 Ginlong Technologies All rights reserved
Captcha*