ReliabilitySafetyCapacity

Solis-(185-255)K-EHV-5G-US

800V: 185K/255K

185-255kW 5G three phase series string inverter have Maximum 28 strings input, support "Y" type connection in DC side. Maximum string input current 13A, support bifacial modules access.Supports anti-PID function to improve system eff iciency. High-precision intelligent strings monitoring reduces fault location time.

185-255kW Three Phase Inverter

Leading Features

  • 99% Max. efficiency (98.5% CEC efficiency)
  • Maximum 28-string input, support "Y" type connection in DC side
  • Maximum string input current 13A, support bifacial modules access
  • Supports anti-PID function to improve system efficiency
  • NEMA 4X protection level, intelligent redundant air cooling design
  • PLC/RS-485 multiple communication modes, flexible monitoring
  • High-precision intelligent strings monitoring reduces fault location time

Technical Specifications

DC Values

  • Max. input voltage:
    1500V
  • Rated voltage:
    950V
  • Start-up voltage:
    620
  • MPPT voltage range:
    600-1500
  • Max. input current:
    14*26A
  • Max. short circuit current:
    14*40A
  • MPPT number:
    14
  • Max. input strings number:
    28

AC Values

  • Rated output power:
    185000W
  • Max. apparent output power:
    185000VA
  • Max. output power:
    185000W
  • Rated grid voltage:
    3Ф/PE, 600V
  • Rated grid frequency:
    60Hz
  • Max. output current:
    178.0A
  • Power Factor:
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi:
    <3%

Efficiency

  • Max efficiency:
    99.0%
  • CEC efficiency:
    98.5%

Protection

  • DC reverse-polarity protection:
    Yes
  • Ground fault monitoring:
    Yes
  • Anti-islanding protection:
    Yes
  • Strings Monitoring:
    Yes
  • I/V Curve scanning:
    Yes
  • Anti-PID function:
    Yes

General Data

  • Dimensions(W*H*D):
    46.0*30.3*15.1in(1170*770*384mm)
  • Weight:
    249.0lbs(113kgs)
  • Topology:
    Transformerless
  • Self consumption:
    <2W
  • Relative humidity:
    0-100%
  • Ambient operating temperature range:
    -13°F to 140°F (-25°C ~ +60°C)
  • Storage environment:
    -40°F to 176°F (-40°C to 80°C)
  • Enclosure type:
    NEMA 4X
  • Cooling concept:
    Intelligent redundant fan-cooling
  • Max.operating altitude without derating:
    13,120ft (4000m)
  • Compliance:
    UL 1741, UL 1741SA, Rule 21, UL 1998, IEEE 1547,FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1, CA Rule 21 Phase II compliant (ready for Phase III)

Features

  • DC connection:
    MC4 connector
  • AC connection:
    OT terminal (max.300 mm²)
  • Display:
    LCD
  • Communication:
    RS485, Optional: PLC
Sales enquiries: ussales@solisinverters.com