Reliability     Safety     Capacity

Solis-(125-255)K-EHV-5G-US

600V: 125K-PLUS / 185K / 185K-PLUS;    800V: 255K / 255K-PLUS

125-255kW three phase series string inverter have Maximum 28 strings input, support "Y" type connection in DC side. Maximum string input current 15A, support bifacial modules access.Supports anti-PID function to improve system eff iciency. High-precision intelligent strings monitoring reduces fault location time.

125-255kW Three Phase Inverter

Leading Features

  • 9/12/14 MPPTs, max. efficiency 99.0% (CEC efficiency 98.3%)

  • Intelligent string monitoring, smart I-V curve scan
  • 150% DC/AC ratio
  • High power tracking density 60MPPT/MW
  • Compatible with 500W+ bifacial modules
  • Remote firmware upgrade with simple operation
  • Globally recognised branded componentry for longer life
  • Built-in PID recovery for better module performance
  • CA Rule 21 compliant and UL 1741 SA Certified
  • Fuse free design, safe and maintenance free
  • AFCI protection, proactively reduces fire risk
  • IP66
  • Power line communication (PLC) (optional)
  • DC side supports "Y" connector
  • Support aluminium wire to reduce cost
  • Reserve DC energy storage access

Technical Specifications

Input DC

  • Rated voltage
    950 V
  • Start-up voltage
    500 V
  • MPPT voltage range
    480-1500 V
  • Max. input current
    9*30 A
  • Max. short circuit current
    9*50 A
  • MPPT number
    9
  • Max. input strings number
    18

Output AC

  • Max. apparent output power
    137.5 kVA
  • Max. output power
    137.5 kW
  • Rated grid voltage
    3Ф/PE, 600 V
  • Rated grid frequency
    60 Hz
  • Max. output current
    132.3 A
  • Power factor
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi
    <3%

Efficiency

  • CEC efficiency
    98.3%

Protection

  • Ground fault monitoring
    Yes
  • Anti-islanding protection
    Yes
  • Strings Monitoring
    Yes
  • Integrated AFCI(DC arc-fault circuit protection)
    Yes
  • I/V Curve scanning
    Yes
  • Integrated PID recovery
    Yes

General Data

  • Weight
    240 lbs (109 kg)
  • Topology
    Transformerless
  • Self consumption (night)
    <2 W
  • Relative humidity
    0-100%
  • Ambient operating temperature range
    -22°F to 140°F (-30°C ~ +60°C )
  • Storage environment
    -40°F to 176°F (-40°C to 80°C)
  • Enclosure type
    TYPE 4X
  • Cooling concept
    Intelligent redundant fan-cooling
  • Max.operating altitude without derating
    13,120ft (4000 m)
  • Compliance
    UL 1741, UL 1741SA, UL 1998, UL1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1, California Rule 21 Phaes II & III

Features

  • AC connection
    OT terminal (max.300 mm²)
  • Display
    LCD
  • Communication
    RS485, Optional: PLC
Sales enquiries: ussales@solisinverters.com
Sitemap  | Privacy policy  | Blog
Copyright@2019 Ginlong Technologies All rights reserved
Captcha*