Select Your Region

Asia/Pacific
中国 India Việt nam 대한민국 Australia ราชอาณาจักรไทย پاکستان
Europe
Türkiye United Kingdom France Deutschland Nederland España Polska Україна Italia Sverige
North America
United States México Canada
South America
Brasil
Africa
South Africa
Other Countries and Regions
Other Countries and Regions

Reliability    Safety    Capacity

Solis-(50-60)K

400V: 50K/60K-4G

Solis-(50-60)kW three-phase series string inverters are suitable for the installation of three-phase input pv system of commercial and industrial PV plants. WhoseTHDi˂3, low harmonic distortion against grid. Adopt anti-resonance signle transformer can connect 6M+ in parallel. Perfect commercial site monitoring solution, intelligent redundancy fan.

50-60kW Three Phase Inverter

Leading Features

  • Max. efficiency 99%
  • Intelligent redundant fan-cooling
  • Wide voltage range and low startup voltage
  • Perfect commercial site monitoring solution
  • THDi<3%, low harmonic distortion against grid
  • 4 MPPT input, each rated current is 28.5A, compatible with high power module
  • Anti-resonance, supporting over 6MW parallelled in one transformer

Technical Specifications

Input DC

  • Rated voltage
    600 V
  • Start-up voltage
    200 V
  • MPPT voltage range
    200-1000 V
  • Max. input current
    4*28.5 A
  • Max. short circuit current
    4*44.5 A
  • MPPT number
    4
  • Max. input strings number
    12

Output AC

  • Max. apparent output power
    55 kVA
  • Max. output power
    55 kW
  • Rated grid voltage
    3/N/PE, 220 V / 380 V, 230 V / 400 V
  • Rated grid frequency
    50 Hz / 60 Hz
  • Rated grid output current
    72.2 A / 76 A
  • Max. output current
    83.3 A
  • Power Factor
    >0.99 (0.8 leading - 0.8 lagging)
  • THDi
    <3%

Efficiency

  • EU efficiency
    98.4%

Protection

  • Short circuit protection
    Yes
  • Output over current protection
    Yes
  • Surge protection
    Yes
  • Grid monitoring
    Yes
  • Anti-Islanding protection
    Yes
  • Temperature protection
    Yes
  • Integrated PID recovery
    Optional
  • Integrated AFCI (DC arc-fault circuit protection)
    Optional
  • Integrated DC switch
    Optional

General Data

  • Weight
    63 kg
  • Topology
    Transformerless
  • Self consumption (night)
    <1 W
  • Operating ambient temperature range
    -25 ~ +60°C
  • Relative humidity
    0-100%
  • Ingress protection
    IP65
  • Cooling concept
    Intelligent redundant fan-cooling
  • Max.operation altitude
    4000 m
  • Safety/EMC standard
    IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4
  • Grid connection standard
    G98 or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530

Features

  • AC connection
    OT terminal
  • Display
    LCD
  • Communication
    RS485, Optional: Wi-Fi, GPRS