ReliabilitySafetyCapacity

Solis-(50-66)K-US-F-SW

50K/50K-F/60K-F/66K-F

The Solis-(50-66)kW three phase series string inverter are suitable for commercial and light industrial PV plants. These units have a compact and light design making them a two-person easy installation. The ultra-low THDi of ˂2% and filter features add multiple layers of protection for the grid and can have up to 6MW in parallel. For easy installation and O&M, these units have a separable wiring box allowing the EPC to install the wiring box ahead of time and add the inverter at a later time. To finish it off these units have multiple options of communication and protocols with free APP and PC monitoring.

50-66kW Three Phase Inverter

Leading Features

  • 2x20Z .LCD Display
  • 10 Year Standard Warranty with extension options
  • Transformer-less three phase design with 480Vac output
  • Web-based data monitoring with downloadable Solis Mobile App
  • 98.6% efficient (98.3% CEC) with ultra-low start up voltage
  • Designed for all commercial, industrial and utility scale applications
  • Integrated Arc Fault Circuit Interrupt (AFCI) option
  • Compact and lightweight design inside a corrosion-resistant NEMA 4X enclosure

Technical Specifications

DC Values

  • Max. power per MPPT(watts) :
    16000
  • Max DC input power(watts):
    64000
  • Max. voltage (volts):
    1000
  • Rated voltage (volts):
    720
  • Startup voltage (volts):
    200
  • Full power MPPT voltage range(volts):
    568-850
  • Operating MPPT voltage range(volts):
    200-850
  • Max. usable input current per MPPT(amps):
    22*4
  • Max. short circuit input current(amps):
    55*4
  • Number of MPPTs:
    4
  • Inputs per MPPT:
    4

AC Values

  • Nominal output power(watts):
    50000
  • Max. apparent output power(VA):
    50000
  • Max. continuous output power(watts):
    50000
  • Nominal grid voltage (volts):
    480
  • Nominal grid frequency (hertz):
    60
  • Operating voltage range(volts):
    422.4-528
  • Nominal grid frequency:
    60
  • Operating frequency range(hertz):
    59.5-60.5
  • Operating phase:
    Three Phase
  • Max. output current(amps):
    60.2
  • Max. overcurrent protection device(amps):
    80
  • Max output fault current and duration:
    80,200ms
  • Output power factor range:
    1 (default) and 0.8leading ... 0.8lagging adjustable
  • Grid current:
    <3%

Efficiency

  • Peak efficiency:
    98.8%
  •  CEC weighted efficiency:
    98.4%
  • MPPT efficiency:
    >99.9%

Protection

  • Temperature protection:
    Yes
  • DC reverse-polarity protection:
    Yes
  • AC  short circuit protection:
    Yes
  • AC  output over current protection:
    Yes
  • Output overvoltage protection-Varistor:
    Yes
  • Ground fault monitoring:
    Yes
  • Grid monitoring:
    Yes
  • Islanding protection:
    Yes
  • Integrated AFCI(DC arc fault protection):
    Yes
  • Integrated DC switch:
    Yes

General Data

  • Dimensions(w*h*d):
    24.9*47.6*14.7in (633*1208*374mm)
  • Weight (inverter)/weight (wiring box):
    147lbs (66.7kgs)/35.4lbs (16kgs)
  • Topology:
    Transformerless
  • Internal consumption:
    <1W(night)
  • Ambient operating temperature range:
    -13°F to 140°F (-25°C to 60°C)
  • Storage Environment:
    -13°F to 176°F (-25°C to 80°C)
  • Enclosure type:
    NEMA 4X
  • Noise emission(typical):
    <30dBA
  • Cooling concept:
    Natural convection
  • Max.operating altitude without derating:
    13120
  • Designed lifetime:
    >20years
  • Compliance:
    UL 1741, UL 1741 SA, ISO-NE, UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1, Rule 21 Phase I and II compliant (ready for Phase III)

Features

  • Communication protocol:
    Modbus RTU (Sunspec compliant)
  • Communication:
    Modbus with optional cellular and Wi-Fi
  • Display:
    LCD,2×20 Z.
  • Warranty:
    10 Years standard (extendable to 20 years)

Case Study

Sales enquiries: ussales@ginlong.com